LX Open Type Low Temperature Cooling Circulator
What is an LX Cooling Circulator?
The LX Cooling Circulator is an innovative cooling system that provides precise temperature regulation for multiple industrial and scientific applications. This efficient device utilizes advanced technology to circulate coolant and maintain stable temperatures throughout its operating range.
Importance of a cooling circulator in various applications
Temperature control is crucial in many fields, such as laboratory research, industrial processes, and medical applications. An LX Cooling Circulator offers a reliable and efficient solution to achieve the desired temperature with accuracy and stability. With precise temperature control, experiments, manufacturing processes, and medical procedures can yield consistent and reliable results.
Quick Details
Voltage | 220v |
Weight | 90kg |
Automatic Grade | Automatic |
Product Attribute
Product Modle | LX-05 | LX-10 | LX-20/30 | LX-50 | LX-100 |
Temperature Range(℃) | -25-Room Tem | -25-Room Tem | -25-Room Tem | -25-Room Tem | -25-Room Tem |
Control Precision(℃) | ±0.5 | ±0.5 | ±0.5 | ±0.5 | ±0.5 |
Volume within Controlled Temperature(L) | 5 | 10 | 20 | 50 | 100 |
Cooling Capacity | 1500~520 | 2600~810 | 3500~1200 | 8600~4000 | 13kw~3.5kw |
Pump Flow(L/min) | 20 | 20 | 20 | 20 | 40 |
Lift(m) | 4~6 | 4~6 | 4~6 | 4~6 | 4~6 |
Supporting Volume(L) | 5 | 10 | 20/30 | 50 | 100 |
Dimension(mm) | 520x350x720 | 580x450x720 | 630x520x1000 | 7600x610x1030 | 1100X900X1100 |
How does an LX Cooling Circulator work?
The LX Cooling Circulator consists of several integral components that work together to achieve optimal temperature regulation. The circulator typically includes a refrigeration system, pump, temperature sensor, and a control interface.
The refrigeration system is responsible for cooling the circulating fluid or coolant, while the pump ensures proper circulation throughout the system. The temperature sensor continuously monitors the fluid's temperature and relays the information to the control interface, which regulates the cooling process based on the user's settings.
Advantages of using an LX Cooling Circulator
Efficient temperature regulation
The LX Cooling Circulator offers precise temperature control, allowing users to set and maintain the desired temperature within a specified range. The device is equipped with advanced temperature sensors and powerful cooling capabilities, ensuring temperature stability even in demanding applications.
Enhanced productivity and performance
Effective temperature control provided by the LX Cooling Circulator contributes to improved productivity and performance in various settings. In research laboratories, experiments can be conducted under well-regulated conditions, minimizing any temperature-related variables. Similarly, in industrial processes, consistent temperature control optimizes efficiency and reduces the likelihood of errors or product defects.
Cost savings and energy efficiency
The LX Cooling Circulator is designed with energy efficiency in mind, utilizing advanced cooling technologies to ensure optimal performance with reduced energy consumption. By maintaining precise temperature control, this system helps to minimize energy waste and lower operating costs.
Applications of LX Cooling Circulators
Laboratory research and testing
LX Cooling Circulators find extensive use in scientific research and testing facilities. These circulators are ideal for temperature-sensitive experiments, such as polymerase chain reactions (PCR), cell culture, and protein crystallization. With their accurate temperature control, LX Cooling Circulators provide a stable environment for scientific discoveries.
Industrial manufacturing processes
In industrial settings, LX Cooling Circulators are employed to regulate the temperature of equipment, machinery, or fluids used in manufacturing processes. From chemical production to semiconductor manufacturing, precise temperature control is essential to ensure consistent output quality and minimize errors.
Medical and pharmaceutical use
Medical and pharmaceutical applications require stringent temperature control to maintain the integrity of medications, samples, and equipment. LX Cooling Circulators are commonly used in medical laboratories, hospitals, and pharmacies to store drugs, vaccines, and other temperature-sensitive materials.
Choosing the right LX Cooling Circulator
Considerations for selecting the appropriate model
When choosing an LX Cooling Circulator, several factors should be considered to ensure optimal performance. These include temperature range, accuracy, pump capacity, and flow rate requirements. It is essential to select a model that meets the specific needs of the intended application.
Temperature range and accuracy
Different applications have varying temperature requirements. Determine the temperature range needed for your specific use case and ensure the LX Cooling Circulator can achieve and maintain those temperatures accurately.
Pump capacity and flow rate
The pump capacity and flow rate of the cooling circulator are important considerations, especially in industrial processes. Evaluate the circulation requirements of your system and select a cooling circulator with appropriate specifications to ensure efficient cooling throughout.
Setting up and operating an LX Cooling Circulator
Installation process and requirements
The installation process of an LX Cooling Circulator may vary depending on the model and specifications. Refer to the manufacturer's instructions for proper installation guidelines. Generally, the process involves connecting the necessary hoses, ensuring proper electrical connections, and placing the cooling circulator in a suitable location.
Instructions for proper use and maintenance
To ensure optimal performance and longevity of the LX Cooling Circulator, it is essential to follow the manufacturer's instructions for use and maintenance. This typically includes guidelines on filling and draining the coolant, cleaning the system, and conducting routine inspections. Regular maintenance and adherence to safety guidelines will extend the lifespan of the cooling circulator.
Troubleshooting common issues with LX Cooling Circulators
Overheating or undercooling problems
If the LX Cooling Circulator is not achieving the desired temperature range, several factors could be causing the issue. Check the set temperature, ensure proper fluid circulation, and inspect the coolant levels and integrity. If problems persist, consult the user manual or contact the manufacturer for further assistance.
Pump or circulation issues
In case of poor circulation or pump-related issues, check for blockages or obstructions in the system. Inspect the pump for proper functionality, check hoses and connections, and ensure there is no air trapped in the system. If the problem persists, contact technical support.
Error codes and how to resolve them
LX Cooling Circulators may have built-in error codes to indicate specific issues. Refer to the user manual for a comprehensive list of error codes and troubleshooting steps. Common error codes could relate to temperature sensor malfunctions, motor failures, or system leaks. Following the manufacturer's guidelines will help identify and resolve any errors.
Safety precautions and guidelines
Electrical safety
LX Cooling Circulators involve electrical components, so it is important to adhere to electrical safety guidelines. Ensure proper grounding, use appropriate electrical connections, and avoid exposing the system to water or other damaging conditions. If in doubt, consult a professional electrician or follow the manufacturer's instructions.
Proper handling of chemicals and substances
Certain applications of LX Cooling Circulators involve the use of chemicals and substances that may be hazardous. Follow safety protocols when handling these materials, wear appropriate personal protective equipment (PPE), and adhere to local regulations and guidelines.
LX Cooling Circulator maintenance tips
Regular cleaning and maintenance routine
Establish a regular cleaning and maintenance routine for the LX Cooling Circulator, which typically includes cleaning the coolant tank, inspecting and replacing filters, and checking for any leaks or damage. Consult the manufacturer's guidelines for specific maintenance requirements.
Replacing parts and filters
Over time, some parts or filters of the LX Cooling Circulator may require replacement. It is essential to use genuine replacement parts and follow the manufacturer's instructions for proper installation. Regularly inspect the system to identify any components that may need replacement.
FAQs
1: How does an LX Cooling Circulator compare to traditional cooling methods?
LX Cooling Circulators provide precise temperature regulation, superior control, and energy efficiency compared to traditional cooling methods, leading to improved productivity and reduced costs.
2: Can an LX Cooling Circulator be used for temperature-sensitive medical samples?
Yes, LX Cooling Circulators are commonly used in medical and pharmaceutical settings to store and regulate the temperature of samples, medications, and vaccines.
3: What factors should I consider when choosing an LX Cooling Circulator for my laboratory?
Factors to consider include temperature range, accuracy, circulation capacity, and the specific requirements of your experiments.
4: How often should the coolant in an LX Cooling Circulator be replaced?
It is recommended to replace the coolant in LX Cooling Circulators according to the manufacturer's guidelines, typically on a regular schedule or when contamination or degradation is detected.
5: What can I do if my LX Cooling Circulator displays an error code?
When encountering an error code, refer to the user manual or contact the manufacturer's technical support for guidance on how to resolve the specific issue.